Product Identification

Product ID:INSULATION ADHESIVE
MSDS Date:02/21/1992
FSC:8040
NIIN:00N033844
MSDS Number: BPTMS

Responsible Party
H B FULLER COMPANY
1200 WOLTERS BOULEVARD
VADNAIS HEIGHTS, MN 55110
US

Emergency Phone: 800-228-5635

Info Phone: 612-481-3300

Preparer: INDUSTRIAL HYGIENE

Cage: ODH19

Contractor
H B FULLER COMPANY
VADNAIS HEIGHTS, MN 55110 US

Telephone: (800) 228-5635

Cage: ODH19

Ingredients

3); (ALPHA-ALUMINA) (SARA III)

CAS: 1344-28-1

RTECS: BD1200000

Fraction By Weight: 1-10%

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 10 MG/M3 TDUST; 9293


(TOLUENE CAS#108-88-3) APPEARS ON NAVY

RTECS: 9999999ZZ


CONSULTATION FROM APPROP HLTH PROFESSIONALS

RTECS: 9999999ZZ


PARAFFIN WAXES AND HYDROCARBON WAXES, CHLORINATED;

CAS: 63449-39-8

RTECS: RV0450000

Fraction By Weight: 1-10%


24 @ 20C.

CAS: 108-88-3

RTECS: XS5250000

Fraction By Weight: 1-10%

OSHA PEL 200 PPM/150 STEL

ACGIH TLV: 50 PPM; 9293

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


ACETIC ACID, VINYL ESTER; (RESIDUAL VINYL ACETATE MONOMER),

CAS: 108-05-4

RTECS: AK0875000

Fraction By Weight: <0.5%

OSHA PEL 10 PPM/15 STEL

ACGIH TLV: 10 PPM/15,A3 STEL;93

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:YES OSHA:NO
Health Hazards Acute and Chronic:EYE:DIRECT CONTACT WITH PRODUCT MAY
CAUSE IRRITATION. SKIN:PROLONGED OR REPEATED CONTACT WITH LIQUID
PRODUCT MAY CAUSE IRRITATION. INHAL:OVEREXPOSURE TO VAPORS IN
POORLY VENTILATED AREAS MAY CAUSE DIZ ZINESS, HEADACHES, NAUSEA OR
UNCONSCIOUSNESS. CHRONIC:OVEREXPOSURE TO VINYL ACETATE IS NOT
EXPECTED TO (EFTS OF OVEREXP)
Explanation of Carcinogenicity:CHLOROCARBON WAXES & HYDROCARBON
WAXES:GROUP 2B (IARC).
Effects of Overexposure:HLTH HAZ:TO OCCUR DURING NORMAL HNDLG/USE OF
PROD. VINYL ACETATE HAS BEEN SHOWN TO CAUSE IRRIT/CANCER IN
INHALATION STUDIES WITH LAB ANIMALS. TEST LEVELS OF 600 PPM CAUSED
AN INCR IN TUMORS IN RESP TR ACT OF TEST ANIMALS. NO TUMORS
OBSERVEDIN ANIMALS EXPOSED AT 50 PPM OR LOWER. NO CANCER OBSERVED
IN HUMANS. (ING 5)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:EYE:FLUSH IMMEDIATELY WITH WATER FOR AT LEAST 15 MINUTES.
CALL MD IF IRRITATION PERSISTS. SKIN:WASH AFFECTED AREA WITH SOAP &
WATER. LAUNDER CONTAMINATED CLOTHING BEFORE REUSE. INHAL:MOVE TO
FRESH AIR . INGEST:CALL MD IMMEDIATELY.

Fire Fighting

Flash Point Method:SCC
Flash Point:>200F,>93C
Extinguishing Media:NON-FLAMMABLE IN LIQUID STATE; USE WATER SPRAY,
FOAM, DRY CHEMICAL OR CARBON DIOXIDE ON DRIED PRODUCT.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:THERE IS THE POSSIBLITY OF PRESSURE
BUILDUP IN CLOSED CONTAINERS WHEN HEATED. WATER SPRAY MAY BE USED
TO COOL CONTAINERS.

Accidental Release

Spill Release Procedures:CONTAIN AND REMOVE WITH INERT ABOSRBENT. KEEP
SPILL OUT OF SEWERS. DIKE IF NECESSARY, CONTAIN SPILL WITH INERT
ABSORBENT AND TRANSFER TO CONTAINERS FOR DISPOSAL. KEEP SPILLED
PRODUCT OUT OF SEWERS, WA TERSHEDS OR WATER SYSTEMS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:ALL PROCEDURES APPROPRIATE FOR A
CONFINED SPACE ENTRY SHOULD BE COMPLETED PRIOR TO PERFORMING ANY
WORK IN A BULK STORAGE TANK.
Other Precautions:IN STORAGE, MONOMER VAPS WILL MIGRATE FROM EMULSION &
ESTABLISH AN EQUILIBRIUM BETWEEN THE HEADSPACE IN STORAGE CONTAINER
& LIQUID EMULSION. LEVELS IN EXCESS OF ACCEPTALBE EXPOS CAN
ACCUMULATE IN NON- VENT HEADSPACES ABOVE THE EMULSION.

Exposure Controls

Respiratory Protection:NOT NORMALLY REQUIRED. USE NIOSH/MSHA APPROVED
RESPIRATOR IF CONDITIONS WARRANT.
Ventilation:STANDARD INDUSTRIAL VENTILATION.
Protective Gloves:RUBBER GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:PROTECTIVE CLOTHING.
Work Hygienic Practices:LAUNDER CONTAMINATED CLOTHING BEFORE REUSE.
Supplemental Safety and Health
WASTE DISP METH:EPA HAZ WASTE REG. LEACHATE TESTS HAVE NOT BEEN
PERFORMED. STATE/LOC HAZ WASTE REGS MAY APPLY IF THEY ARE DIFFERENT
FROM FED REG. SOLIDIFY & DISP OF IN APPRVD LANDFILL. FOR ADDL WASTE
DISP ASSIST, CONSULT H.B. FULLER ENVIRONMENTAL SERVICES AT
612-481-1588. DISP MUST BE I/A/W LOC, STATE & FED REGS.

Chemical Properties

Boiling Pt:B.P. Text:>200F,>93C
pH:5.5
Solubility in Water:MISCIBLE
Appearance and Odor:LIQUID

Stability

Stability Indicator/Materials to Avoid:YES
NOT ESTABLISHED.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:INCOMPLETE COMBUSTION CAN YIELD LOW
MOLECULAR WEIGHT HYDROCARBONS, CO, HCL, PHOSGENE.

Disposal

Waste Disposal Methods:TO THE BEST OF OUR KNOWLEDGE, THIS PRODUCT DOES
NOT MEET THE DEFINITION OF HAZ WASTE UNDER U.S. EPA HAZ WASTE REGS
40 CFR 261. IT DOES NOT CNTN ANY ADDED MATLS W/KNOWN LEVELS OF TCLP
CONSTITUENTS AS I DENTIFIED IN SECTION 261.24 OF US. EPA(SUPP DATA)

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.